
Applications
Modular and prefab
A foundation process aligned with factory-made structures: fast, repeatable, precise and capable of supporting relocatable design strategies where engineered accordingly.
Your building is pre‑engineered. Your foundation can be too.
PEN pairs a factory-made M50 node and galvanized steel nails with an interface designed around your building system. The opportunity is a repeatable foundation interface, not just faster foundations.
Factory speed above ground. Conventional civil work below it.
Fabricated, checked and ready to assemble on a known date.
Start with the building system.
An OEM integration reviews your support conditions once, then reuses the result across models.
M50 precast node
A controlled structural component.
Galvanized steel nails
Typical four-nail configuration.
Engineered interface
Bolted Variant A for steel, LGSF and prefab bases.
Site-specific engineering
A repeatable superstructure does not remove soil qualification.
Engineer the interface once.
- 01
Representative model
One building type with its reactions.
- 02
Interface review
Base plate, bolts, tolerances.
- 03
Pilot project
One live site.
- 04
Connection validation
Measured on the pilot.
- 05
Repeatable intake
Standard inputs for every order.
Build a repeatable process around one good interface.
One precast node. Four engineered nails. Ready to build.
PEN Foundation, the Pre-Engineered Nail Foundation System, is a patented, biomimetic foundation inspired by the way tree roots distribute load through soil. A high-strength precast node sits at ground level and transfers structural loads through four inclined steel nails driven into the surrounding soil. The system is designed for the project’s soil, structural loads and layout, then installed without excavation, formwork or on-site foundation curing.
- 01
Zero excavation
Soil layers, drainage paths and terrain are preserved.
- 02
Installed within hours
No on-site foundation curing cycle at the end of the sequence.
- 03
Immediate load readiness
Ready for approved superstructure connection after installation and quality checks.
- 04
Less concrete and water
Substantially lower concrete and water use than conventional RCC footings.
- 05
Qualified by evidence
Soil- and load-qualified design supported by testing, simulation and field deployment.
Four steps from project enquiry to structure
PEN is specified for the project, not sold as an unqualified off-the-shelf footing. The layout, number of points and installation configuration follow from the ground and the structure.
- 01
Assess
We review the project location, structural system, column reactions, site access and available soil information. Where required, soil suitability is established through appropriate field or geotechnical inputs.
- 02
Engineer
Our engineers develop the foundation layout and configuration for the approved project loads and qualified soil conditions. Point count, position, nail geometry and embedment are selected as part of the design process.
- 03
Install
The precast nodes are positioned, the engineered nails are driven into the soil and the system is completed in accordance with the approved installation method. There is no excavation, formwork or on-site foundation curing cycle.
- 04
Build
Once installation and quality checks are completed, the superstructure can connect to the node and construction can continue without the conventional foundation waiting period.
Questions about modular and prefab
Why use PEN under modular and prefab buildings?
A foundation process aligned with factory-made structures: fast, repeatable, precise and capable of supporting relocatable design strategies where engineered accordingly.
Why is it called “pre-engineered”?
The node is cast and cured in the factory to a fixed model, CD-PEN-32.3.2.1500, and arrives ready to use — nothing is mixed, formed or cured on your site. What is engineered per project is the layout and the driving: the point count, the embedment and a batter angle set between 40° and 51° for your ground.
Is it suitable for permanent structures?
Yes — it is carrying permanent buildings today, including a library retrofit and rehabilitation housing. The system is engineered for low-rise construction; structures above G+2 are on the development roadmap rather than in the current product. Components are also recoverable at end of life, which makes it equally suited to relocatable and temporary buildings.
How long does installation take?
Around two hours per foundation point, and the point is load-bearing the moment the last nail is driven and grouted. There is no curing period, so structural work can begin the same day.
How many units will my project need?
It depends on the structure and the ground. As a rough indication, a G+1 house typically needs 16–20 PEN units. The actual point count comes out of the engineering assessment.
Other applications

Residential
A hassle-free foundation sequence with fewer wet-work dependencies, less site congestion and installation that follows the approved plan without a month-long footing cycle.

Commercial
Faster foundation completion can bring the structure and the revenue-generating asset forward, while keeping the site cleaner and reducing programme uncertainty.

Eco-resorts and farmstays
Zero excavation helps preserve tree roots, soil structure, slopes and the natural character guests come to experience. Earlier project completion can also bring operations and revenue forward.

Low-span industrial
Repeated column grids and schedule-sensitive delivery make suitable sheds and light industrial structures a strong application for a pre-engineered foundation system.

Ground-mounted solar
An application under development, focused on faster repetitive installation and reduced concrete, water, spoil and site disturbance. Published as a development pathway until the solar-specific product and economics are fully validated.
